{"id":175,"date":"2026-07-23T15:06:59","date_gmt":"2026-07-23T07:06:59","guid":{"rendered":"http:\/\/localhost:88\/?p=175"},"modified":"2026-07-23T15:06:59","modified_gmt":"2026-07-23T07:06:59","slug":"dmt2000-h2-multi-channel-electro-hydraulic-servo-loading-system","status":"publish","type":"post","link":"https:\/\/www.huasintest.com\/de\/dmt2000-h2-multi-channel-electro-hydraulic-servo-loading-system\/","title":{"rendered":"Dmt2000-H2 Mehrkanaliges elektrohydraulisches Servo-Belastungssystem"},"content":{"rendered":"<table style=\"width: 100%; border-collapse: collapse;\" border=\"1\" cellspacing=\"0\" cellpadding=\"10\">\n<thead>\n<tr style=\"background: #d62828; color: #ffffff; text-align: center;\">\n<td style=\"text-align: center;\" align=\"center\"><strong>Modell<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>DMT2505-H2<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>DMT2106-H2<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>DMT2156-H2<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>DMT2206-H2<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>DMT2306-H2<\/strong><\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"text-align: center;\">Maximale Pr\u00fcfkraft (kN)<\/td>\n<td style=\"text-align: center;\">500<\/td>\n<td style=\"text-align: center;\">1000<\/td>\n<td style=\"text-align: center;\">1500<\/td>\n<td style=\"text-align: center;\">2000<\/td>\n<td style=\"text-align: center;\">3000<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Belastungskanal \u2013 Menge &amp; Typ<\/td>\n<td style=\"text-align: center;\" colspan=\"5\">2 Kan\u00e4le, horizontaler Servoaktuator, vertikaler Servoaktuator oder Hydraulikzylinder<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Pr\u00fcfkraftgenauigkeit<\/td>\n<td style=\"text-align: center;\" colspan=\"5\">\u00b11,0% FS innerhalb des Messbereichs von 2%~100%FS<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Kolbenhub (mm)<\/td>\n<td style=\"text-align: center;\" colspan=\"5\">Standard: 200, 300; Optional: 400, 500<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Aktuatorkonfiguration<\/td>\n<td style=\"text-align: center;\" colspan=\"5\">Einfachstange doppeltwirkend; vorderes Gelenklager &amp; hinterer Flansch oder vordere &amp; hintere Gelenklager<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Rahmenstruktur<\/td>\n<td style=\"text-align: center;\" colspan=\"5\">Stahlportalrahmen, leitspindelverstellbarer Portalrahmen, selbstreagierender Portalrahmen<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Pr\u00fcfraumh\u00f6he (mm)<\/td>\n<td style=\"text-align: center;\" colspan=\"5\">Kundenspezifisch<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Optionale Pr\u00fcfvorrichtungen<\/td>\n<td style=\"text-align: center;\" colspan=\"5\">Druckvorrichtung, (3-Punkt-, 4-Punkt-) Biegevorrichtung, Zugvorrichtung<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Funktionen<\/td>\n<td style=\"text-align: center;\" colspan=\"5\">Verwendet dreifache geschlossene Regelung von Kraft, Weg und Verformung (oder externem Wegsensor). Der Computer zeigt Daten und Kurven der drei Parameter an.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>Model DMT2505-H2 DMT2106-H2 DMT2156-H2 DMT2206-H2 DMT2306-H2 Maximum Test Force (kN) 500 1000 1500 2000 3000 Loading Channel Quantity &amp; Type 2 channels, horizontal servo actuator, vertical servo actuator or hydraulic jack Test Force Accuracy \u00b11.0% FS within measuring range of 2%~100%FS Actuator Stroke (mm) Standard: 200, 300; Optional: 400, 500 Actuator Configuration Single rod double-acting; [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":131,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[19],"tags":[],"class_list":["post-175","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-structural-loading-test-system"],"_links":{"self":[{"href":"https:\/\/www.huasintest.com\/de\/wp-json\/wp\/v2\/posts\/175","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.huasintest.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.huasintest.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.huasintest.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.huasintest.com\/de\/wp-json\/wp\/v2\/comments?post=175"}],"version-history":[{"count":1,"href":"https:\/\/www.huasintest.com\/de\/wp-json\/wp\/v2\/posts\/175\/revisions"}],"predecessor-version":[{"id":178,"href":"https:\/\/www.huasintest.com\/de\/wp-json\/wp\/v2\/posts\/175\/revisions\/178"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.huasintest.com\/de\/wp-json\/wp\/v2\/media\/131"}],"wp:attachment":[{"href":"https:\/\/www.huasintest.com\/de\/wp-json\/wp\/v2\/media?parent=175"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.huasintest.com\/de\/wp-json\/wp\/v2\/categories?post=175"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.huasintest.com\/de\/wp-json\/wp\/v2\/tags?post=175"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}