| Maximum Test Force (kN) |
100 |
300 |
500 |
600 |
1000 |
| Test Force Accuracy |
±1.0% (Precision type: ±0.5%), measuring range 1%~100%FS |
| Actuator Stroke (mm) |
Standard: 150; Optional: 200, 300 |
| Actuator Configuration |
Single rod double-acting, front spherical hinge & rear flange |
| Frame Structure |
Steel gantry frame, lead-screw adjustable gantry frame, self-reaction gantry frame |
| Test Space Height (mm) |
Customized |
| Optional Test Fixtures |
Compression fixture, (3-point, 4-point) bending fixture, tension fixture |
| Loading Speed Range |
0.01~90 mm/min (Max 150 mm/min) |
0.01~45 mm/min |
| Recommended Hydraulic Power Unit Specification |
– |
| Functions |
Adopts triple closed-loop control of force, displacement and deformation (or external displacement sensor). The touch screen displays data and curves of the three parameters. |
| Remarks |
Data acquisition instrument and dual-output force sensor are optional. |