{"id":175,"date":"2026-07-23T15:06:59","date_gmt":"2026-07-23T07:06:59","guid":{"rendered":"http:\/\/localhost:88\/?p=175"},"modified":"2026-07-23T15:06:59","modified_gmt":"2026-07-23T07:06:59","slug":"dmt2000-h2-multi-channel-electro-hydraulic-servo-loading-system","status":"publish","type":"post","link":"https:\/\/www.huasintest.com\/fr\/dmt2000-h2-multi-channel-electro-hydraulic-servo-loading-system\/","title":{"rendered":"Syst\u00e8me de chargement asservi \u00e9lectro-hydraulique multicanal Dmt2000-H2"},"content":{"rendered":"<table style=\"width: 100%; border-collapse: collapse;\" border=\"1\" cellspacing=\"0\" cellpadding=\"10\">\n<thead>\n<tr style=\"background: #d62828; color: #ffffff; text-align: center;\">\n<td style=\"text-align: center;\" align=\"center\"><strong>Mod\u00e8le<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>DMT2505-H2<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>DMT2106-H2<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>DMT2156-H2<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>DMT2206-H2<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>DMT2306-H2<\/strong><\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"text-align: center;\">Force d'essai maximale (kN)<\/td>\n<td style=\"text-align: center;\">500<\/td>\n<td style=\"text-align: center;\">1000<\/td>\n<td style=\"text-align: center;\">1500<\/td>\n<td style=\"text-align: center;\">2000<\/td>\n<td style=\"text-align: center;\">3000<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Quantit\u00e9 et type de canaux de chargement<\/td>\n<td style=\"text-align: center;\" colspan=\"5\">2 canaux, servo-actionneur horizontal, servo-actionneur vertical ou v\u00e9rin hydraulique<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Pr\u00e9cision de la force d'essai<\/td>\n<td style=\"text-align: center;\" colspan=\"5\">\u00b11,0% FS dans la plage de mesure de 2%~100%FS<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Course de l'actionneur (mm)<\/td>\n<td style=\"text-align: center;\" colspan=\"5\">Standard : 200, 300 ; En option : 400, 500<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Configuration de l\u2019actionneur<\/td>\n<td style=\"text-align: center;\" colspan=\"5\">Simple tige \u00e0 double effet ; rotule sph\u00e9rique avant et bride arri\u00e8re, ou rotules sph\u00e9riques avant et arri\u00e8re<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Structure du b\u00e2ti<\/td>\n<td style=\"text-align: center;\" colspan=\"5\">B\u00e2ti portique en acier, b\u00e2ti portique r\u00e9glable par vis-m\u00e8re, b\u00e2ti portique \u00e0 auto-r\u00e9action<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Hauteur de l'espace d'essai (mm)<\/td>\n<td style=\"text-align: center;\" colspan=\"5\">Personnalis\u00e9<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Montages d\u2019essai en option<\/td>\n<td style=\"text-align: center;\" colspan=\"5\">Montage de compression, montage de flexion (3 points, 4 points), montage de traction<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Fonctions<\/td>\n<td style=\"text-align: center;\" colspan=\"5\">Adopte une triple r\u00e9gulation en boucle ferm\u00e9e de la force, du d\u00e9placement et de la d\u00e9formation (ou capteur de d\u00e9placement externe). L'ordinateur affiche les donn\u00e9es et les courbes des trois param\u00e8tres.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>Model DMT2505-H2 DMT2106-H2 DMT2156-H2 DMT2206-H2 DMT2306-H2 Maximum Test Force (kN) 500 1000 1500 2000 3000 Loading Channel Quantity &amp; Type 2 channels, horizontal servo actuator, vertical servo actuator or hydraulic jack Test Force Accuracy \u00b11.0% FS within measuring range of 2%~100%FS Actuator Stroke (mm) Standard: 200, 300; Optional: 400, 500 Actuator Configuration Single rod double-acting; [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":131,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[19],"tags":[],"class_list":["post-175","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-structural-loading-test-system"],"_links":{"self":[{"href":"https:\/\/www.huasintest.com\/fr\/wp-json\/wp\/v2\/posts\/175","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.huasintest.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.huasintest.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.huasintest.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.huasintest.com\/fr\/wp-json\/wp\/v2\/comments?post=175"}],"version-history":[{"count":1,"href":"https:\/\/www.huasintest.com\/fr\/wp-json\/wp\/v2\/posts\/175\/revisions"}],"predecessor-version":[{"id":178,"href":"https:\/\/www.huasintest.com\/fr\/wp-json\/wp\/v2\/posts\/175\/revisions\/178"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.huasintest.com\/fr\/wp-json\/wp\/v2\/media\/131"}],"wp:attachment":[{"href":"https:\/\/www.huasintest.com\/fr\/wp-json\/wp\/v2\/media?parent=175"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.huasintest.com\/fr\/wp-json\/wp\/v2\/categories?post=175"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.huasintest.com\/fr\/wp-json\/wp\/v2\/tags?post=175"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}